[Date Prev][Date Next][Thread Prev][Thread Next][Date Index][Thread Index]
Re: [ipcdn] SigMIB Draft 10
Hi -
What is meant by "not used" in the proposed DESCRIPTION clause?
Specifically, what happens when processing a get(next/bulk) request
and pktcSigDevCidMode is not rpAsETS?
Also, what is the motivation for requiring inconsistent value errors
for all set requests when pktcSigDevCidMode is not rpAsETS?
If the value is ignored under those circumstances, it would seem
simpler to accept it as long as it is within the SYNTAX range.
Randy
----- Original Message -----
From: "Freyman Phillip-FPF300" <phillipfreyman at motorola.com>
To: <ipcdn at ietf.org>
Sent: Tuesday, March 28, 2006 1:52 PM
Subject: [ipcdn] SigMIB Draft 10
Colleagues,
A situation has been raised in Belgium where the local telephony
requirements exceed the ETSI EN 300 369-1 definition for RP-AS
In the ETSI document RP-AS is defined as 200 ms to 300 ms in duration.
In the Belgium Belgacom document the RP-AS is implied as being 340 ms
and in field experience this as been verified. Some CPE devices do not
respond if the RP-AS is less than 340 ms.
It does not appear that the maximum ETSI value of RP-AS is adequate and
it does not appear that placing CID during the normal ring cadence is
acceptable.
We therefore have two standards which do not overlap and therefore we
must define a new SigMIB object to define the RP-AS duration from the
ETSI 200 ms min to something in excess of the Belgacom nominal value of
340 ms.
In the following text draft, I have defined a new object (#41) with a
range of 200-500 ms.
Page 7 Add:
pktcSigDevrpAsDtsDuration - this international object sets the
duration of
the ring pulse alerting signal prior to CID signaling. Variations in
national standards cause CID failure if RP-AS is not defined by local
requirements.
Page 44 Add:
pktcSigDevrpAsDtsDuration OBJECT-TYPE
SYNTAX Unsigned32 (200..500)
UNITS "Milliseconds"
MAX-ACCESS read-write
STATUS current
DESCRIPTION
" This object specifies the duration of the rpASDTS ring
pulse prior
to the start of the transmission of the
FSK or DTMF containing the Caller ID information. It is
only used when pktcSigDevCidMode is rpAsETS. The
following table defines the default values for this object
depending on the signal type:
pktcSigDevCidMode Default
duringringingETS not used
dtAsETS not used
rpAsETS 250
lrAsETS not used
lrETS not used
An attempt to set this object while the value of
pktcSigDevCidMode is not rpAsETS will result in
an 'inconsistent value' error."
REFERENCE
"ETSI-EN-300-659-1 Specification and Belgacom
BGC_D_48_9811_30_09_EDOC version 3.3"
DEFVAL { 250 }
::= {pktcSigDevConfigObjects 41 }
Page 60 Add last line
pktcInternationalGroup OBJECT-GROUP
OBJECTS {
pktcNcsEndPntConfigMinHookFlash,
pktcNcsEndPntConfigMaxHookFlash,
pktcNcsEndPntConfigPulseDialInterdigitTime,
pktcNcsEndPntConfigPulseDialMinMakeTime,
pktcNcsEndPntConfigPulseDialMaxMakeTime,
pktcNcsEndPntConfigPulseDialMinBreakTime,
pktcNcsEndPntConfigPulseDialMaxBreakTime,
pktcSigDevRingCadence,
pktcSigDevCidSigProtocol,
pktcSigDevCidDelayAfterLR,
pktcSigDevCidDtmfStartCode,
pktcSigDevCidDtmfEndCode,
pktcSigDevVmwiSigProtocol,
pktcSigDevVmwiDelayAfterLR,
pktcSigDevVmwiDtmfStartCode,
pktcSigDevVmwiDtmfEndCode,
pktcSigDevrpAsDtsDuration,
I understand it may delay Draft 10 but I think it is necessary.
Regards,
Phillip Freyman
Distinguished Member of the Technical Staff
Science Advisory Board Associate
Motorola, Inc.
Connected Home Solutions IPS
IP System Engineering
21440 West Lake Cook Road
Deer Park, IL 60010
--------------------------------------------------------------------------------
> _______________________________________________
> IPCDN mailing list
> IPCDN at ietf.org
> https://www1.ietf.org/mailman/listinfo/ipcdn
>